Polarization Independent (SM) Fiber Circulator
This is the default circulator configuration with the 1 - 2 path the HP leg. This is typically used when you have a high input power and a low return signal.

OC-3-1550        Standard Circulator Configuration
Operating Wavelength: 1550 nm ± 20 nm
Isolation (2 - 1 ): > 35 dB
Isolation ( 3 - 2): > 32 dB
Insertion Loss ( 1 - 2 ): 0.9 - 1.3 dB
Insertion Loss ( 2 - 3 ): 0.9 - 1.3 dB
Crosstalk ( 1 - 3 , 3 - 1 ): > 40 dB
Return Loss: < 55 dB
PDL: < 0.1 dB
PMD: < 0.1 ps
Epoxy-Free Beam Path 1 - 2
Power Handling (1 - 2 ): 5 W
Power Handling (2 - 3 ): 500 mW

 


 

Polarization Independent (SM) Fiber Circulator
This is the default circulator configuration with the 2 - 3 path the HP leg. This is typically used when you have a low input power and an amplified return signal.

OC-3-1550-HP        Standard Circulator Configuration
Operating Wavelength: 1550 nm ± 20 nm
Isolation (2 - 1 ): > 33 dB
Isolation ( 3 - 2): > 35 dB
Insertion Loss ( 1 - 2 ): 0.9 - 1.3 dB
Insertion Loss ( 2 - 3 ): 0.9 - 1.3 dB
Crosstalk ( 1 - 3 , 3 - 1 ): > 40 dB
Return Loss: < 58 dB
PDL: < 0.1 dB
PMD: < 0.1 ps
Epoxy-Free Beam Path 2 - 3
Power Handling (1 - 2 ): 500 m W
Power Handling (2 - 3 ): 5 W

 

 


 

Polarization Independent (SM) Fiber Circulator
Typically used in amplifier systems where a low power signal is sent to the amplifier (1 - 2) then the high power signal returns from (2 - 3). Note the different port configuration below.

OC-3-1550-HP2      High Power Configuration
Operating Wavelength: 1550 nm ± 20 nm
Isolation (2 - 1 ): > 33 dB
Isolation ( 3 - 2): > 33 dB
Insertion Loss ( 1 - 2 ): 1.0 - 1.5 dB
Insertion Loss ( 2 - 3 ): 1.0 - 1.5 dB
Crosstalk ( 1 - 3 , 3 - 1 ): > 40 dB
Return Loss: < 55 dB
PDL: < 0.1 dB
PMD: < 0.2 ps
Epoxy-Free Beam Path 1 - 2 , 2 - 3
Power Handling (1 - 2 ): 5 W
Power Handling (2 - 3 ): 5 W


Polarization Independent (SM) Fiber Circulator
This is the default circulator configuration with the 1 - 2 path the HP leg. This is typically used when you have a high input power and a low return signal.

OCT-3-1550           Tandem or Double Stage Isolation
Operating Wavelength: 1550nm ± 20nm
Isolation (2 - 1 ): > 58 dB
Isolation ( 3 - 2): > 50 dB
Insertion Loss ( 1 - 2 ): 0.8 - 1.5 dB
Insertion Loss ( 2 - 3 ): 0.8 - 1.5 dB
Crosstalk ( 1 - 3 , 3 - 1 ): > 50 dB
Return Loss: < 55 dB
PDL: < 0.1 dB
PMD: < 0.1 ps
Power Handling (1 - 2 ): 5W
Power Handling (2 - 3 ): 500 mW

 


Polarization Dependent (PM) Fiber Circulator
Polarization dependent circulator using PM fiber on all ports. High power on both legs (1 - 2 and 2 - 3). When connectorized the slow axis of the PM fiber is aligned to the connector key.

OC-3-1550-PM        Standard Circulator Configuration
Operating Wavelength: 1550nm ± 20nm
Fiber: PM Panda
Isolation (2 - 1 ): > 35 dB
Isolation ( 3 - 2): > 32 dB
Insertion Loss ( 1 - 2 ): 09 - 1.3 dB
Insertion Loss ( 2 - 3 ): 0.9 - 1.3 dB
Crosstalk ( 1 - 3 , 3 - 1 ): > 50 dB
Return Loss: < 55 dB
Power Handling (1 - 2 ): 5W

 

 